누설전류계 30032A
  • 누설전류계 30032A
  • 누설전류계 30032A
  • 누설전류계 30032A

누설전류계 30032A

공유
짧은설명
AC Leakage Current Mini Clamp-on -
3/30mA/30/60 Amp,
Harmonic filter ON/OFF switch
정가
975,000
판매가
828,000
배송비
0원 조건별배송 지역별추가배송비
 / 
방문 수령지 : 서울특별시 구로구 디지털로 288 (대륭포스트타워1차) 1404
모델명
30032A
상품 무게
210g
제조사
YOKOGAWA
원산지
JAPAN
누설전류계 30032A
0
총 상품금액
총 할인금액
총 합계금액

상품상세정보

    


30032A 1mA/60A Leakage Current Clamp-On Meters

 

 

Leakage Current Clamp-On Meters


 

 

Product Overview


Harmonic Filter Function (Available in the Yokogawa 30032A)


1. What is a Harmonic?

Harmonic refers to sinusoidal quantity having a frequency that is an integral multiple of the fundamental frequency (for example, the commercial frequency). When a harmonic is superimposed on the fundamental frequency, the waveform is distorted.


2. Why is it Necessary to Accurately Measure the Leakage Current of the Fundamental Frequency (Commercial Frequency)?

One problem when measuring the leakage current to check the isolation of electrical circuits in power distribution equipment is that the electrical 

isolation cannot be correctly understood due to the influence of a harmonic current. That is, the leakage current flowing from the electrical circuit 

to ground is very small so that, in order to check the isolation of electrical circuits by means of the leakage current, it is necessary to remove the 

harmonic component of the leak current and measure only the current of the fundamental frequency (commercial frequency).


3. The Yokogawa 30032A Employs a Harmonic Filter

Conventional leakage clamp-on testers could not sufficiently remove harmonic current components so measured leakage current values were often larger than the specified value due to the influence of a harmonic current. In this case, retesting with an insulation tester was required, resulting in increased effort and cost for the test. Under these circumstances, Yokogawa Meters & Instruments Corporation has developed the leakage clamp-on tester 30032A, which employs a high-performance harmonic filter that can accurately measure just the fundamental frequency component of the leakage current.

  

 

Product Specifications  

 

Description

Leakage Current Mini Clamp-on; 3/30mA/30/60 Amp

Method of detection

Mean Value

Display

(Bar-graph display: 32 segments)
LCD (Digital display: 3200 counts)

Range Switching

Auto-range

Operating temperature and humidity

0 - 50°, 80% RH or less (no condensation)

Influence of external magnetic field

0.0005% typical 1 (on current value of adjacent cable)

Influence of conductor position

Within accuracy

Safety Standard

Approved for conformity to EN 61010-1,EN 61010-2-032

Circuit voltage

300 Vrms or less

Withstanding voltage

3.7 kV AC for one minute

Power Supply

One CR2032 (Coin-shaped) 3 V battery

Battery Life

Approx. 90 hours (when continuously used)

Auto power-off

Approx. 10 minutes

Diameter of measurable conductor

40 at maximum mm

Dimensions

Approx. 70 (W) x 176 (H) x 25 (D) mm

Weight

Approx. 200 g

Accessories

Instruction manual, battery, Soft case

AC Current

3/30 mA, 30/60A

Frequency Characteristics

50/60 Hz

Accuracy (50/60Hz)

1.0 + 5 (0~30mA)
1.0 + 5 (0~50A)
5.0 + 5 (50~60A)

Measurement Cycle

2 times/second (Digital display), 12 times/second (Bar-graph display)

Temperature Coefficient

0.05% of range /°C or less (within the ranges of 0-18° and 28-50° for measurement of 0-50 A)

Note

  • Can measure leakage currents of 1 mA, which is useful for checking the insulation of low-voltage circuits              and electrical components.
  • Can measure a broad range of currents from leakage currents (at a resolution of 0.001 mA) to load currents         up to 60 A.
  • Typical influence (on the current value of an adjacent cable) from an external magnetic field is 0.0005%.
  • Durability of clamp: More than 50,000 opening/closing events
  • Twice the tensional strength of Yokogawa M&C's earlier model clamps
  • The clamp lever is lengthened by 30%, enabling smooth opening/closing of the clamp even for thick cables           of 40mm in diameter.
  • Approved for conformity to safety standards EN 61010-1 and EN 61010-2-032 (CAT III 300V, pollution                   degree2)

 

 

At 23°C±5°C,75%RH or less

Accuracy: ±( % rdg + dgt) = ±(% readout + value of least significant digit)

AC current

3/30mA, 30/60A

Frequency characteristics

50/60Hz

Accuracy

50/60Hz

1.0 + 5(0~30mA)

1.0 + 5(0~50A)

5.0 + 5 (50-60A) 

 

 

 

AC current measurement

Filter function OFF

Accuracy: ± (% of reading + digits)

Range

Resolution

Accuracy

Maximum
Allowable Current

3mA

0.001mA

0.010 < I ≤32.70mA:
1.0%+5

3.270mA

30mA

0.01mA

32.70mA

30A

0.01A

0.05 < I ≤50.0A:1.0%+5
50.0 < I ≤60.6A:5.0%+5

32.70A

60A

0.1A

60.6A

Filter function ON

3mA

0.001mA

0.010 < I ≤32.70mA:
1.5%+5

3.270mA

30mA

0.01mA

32.70mA

30A

0.01A

0.05 < I ≤50.0A:1.5%+5
50.0 < I ≤60.6A:5.5%+5

32.70A

60A

0.1A

60.6A

Note: Input current of 2nd-order and higher harmonics
: 150 mA rms maximum in the 3 mA/30 mA range
: 62 A rms maximum in the 30 A/60 A range
Filter specifications (3 mA and 30 mA ranges and 30 A and 60 A ranges)
Amplitude ratio at 100 Hz: -38 dB (1.26%) or less (typical: -41 dB)
Amplitude ratio at 120 Hz: -53 dB (0.22%) or less (typical: -56 dB)
Zero correction
3 mA range: Displays 0.000 mA (zero) when 0.010 mA < I
30 A range: Displays 0.00 A (zero) when 0.05 A < I

 


 

 

 Key Features 
   

◆ Leakage current measurement range from 3mA to 60A

◆ Diameter of measurable conductor: 40 mm max.

◆ Easier and clear display

 


 

Accessoires Included


User’s manual
◆ Batteries 
◆ Soft carrying case (RB057)

 

 

Additional Information 

 

Weight

200 g

Dimensions

70 (W) x 176 (H) x 25 (D) mm 

  

 

 

※ 자세한 사항은 'DataSheet'나 'Quick Start Guide'를 참조해 주세요.      



상품필수 정보

품명 및 모델명 상품상세참조 제조국 또는 원산지 상품상세참조
제조자, 수입품의 경우 수입자를 함께 표기 상품상세참조 A/S 책임자와 전화번호 또는 소비자상담 관련 전화번호 상품상세참조
법에 의한 인증·허가 등을 받았음을 확인할 수 있는 경우 그에 대한 사항 상품상세참조

배송안내

- 배송비 : 기본배송료는 3,000원 (제주도 및 일부 도서산간 지역은 배송비가 추가됩니다.) 

    \200,000원 이상 구매시 무료배송

- 오후 5시 이전 주문시 통상적으로 당일 발송

- 제품 품절인 경우가 있기 때문에 납기일 확인 후 주문 부탁드립니다.

- 배송예정일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과는 차이가 발생할 수 있습니다.

- 본 상품의 배송 가능일은 결제완료 된 날로부터 2~3 영업일입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다.

교환 및 반품안내

- 특수 제품, 주문 제품 등의 경우, 그 특성상 주문이 접수된 후 취소 및 환불이 불가합니다. 주문 전 충분히 상담하신 후 구매해 주세요.

  (특수 제품이란, 보유제품이 아닌 주문 후 생산하며 출고하는 제품을 말합니다.)  

- 제품 특성상 주문이 접수된 후 단순 변심에 의한 취소 및 환불은 당일에 한해 가능합니다. (취소및 환불 접수전 반드시 고객센터를 통해 연락바랍니다.)

- 전자 제품 특성상 제품포장 개봉 후에는 교환 및 환불이 불가능합니다. (제품 하자 제외) 

- 모든 교환·반품은 수령 후 7일 이내 접수되어야 하며, 접수 전에 고객센터로 문의해 주셔야 진행이 가능합니다. 

- 미개봉 제품의 경우, 받으신 날로부터 7일 이내 접수하시면 교환이 가능합니다.

- 개봉하신 제품은 7일 이내라도 교환이 불가합니다.(제품 하자 제외)

- 배송된 날로부터 7일이 지나면 어떤 교환·반품도 불가하므로 받으시면 제품 상태를 꼭 확인해 주세요. (제품 하자 포함) 

- 소비자 변심에 의한 교환은 왕복 운임을 부담하셔야 합니다.


환불안내

- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.

- 주문 제품, 특수 제품의 경우 교환/반품이 불가합니다.

- 주문 전 충분한 상담을 하신 후, 신중히 구매해 주세요.

- 환불신청시 왕복 운송료를 부담하셔야 합니다. 

AS안내

※ 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.

 

:: A/S 처리 문의 ::

전화 : 02) 2617-0787

E-MAIL : kdk@kdk.co.kr

 

⊙ A/S처리기간은 5일~4주 정도로, 제품에 따라 상이합니다. 

  

⊙ 무상보증수리 : 제조사의 품질보증 기간에 따라 다릅니다. 무상보증 수리기간은 일반적으로 1년, 3년입니다.

    무상보증수리를 위한 왕복 배송료는 티엠마켓에서 부담합니다.

    단, 무상보증기간일지라도 소모품 교체나 소비자 과실일 경우 비용이 추가될 수 있습니다.

     

⊙ 유상수리 : 무상보증 기간이 지난 제품에 이상이 생겼을 경우에는 유상수리를 하셔야 합니다.

       기본적으로, 수리를 위해 티엠마켓으로 보내시는 배송료는 고객 부담, 받으시는 배송료는 티엠마켓에서 부담합니다.

       타사에서 구입한 제품도 티엠마켓에서 수리 가능합니다.

이미지 확대보기누설전류계 30032A

누설전류계 30032A
  • 누설전류계 30032A
  • 누설전류계 30032A
  • 누설전류계 30032A
닫기

비밀번호 인증

글 작성시 설정한 비밀번호를 입력해 주세요.

닫기

장바구니 담기

상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?

찜 리스트 담기

상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?



스크롤 우측 배너
상단으로 이동